Fibre Channel Host Adapter FC25/S
SS4 SS5 SS10 SS20 SS600
SS1000 SC2000 A11 A12 A14
Option 1057
501-2069 501-2553
FRU w/o 370-1426 w 370-1426
Notes:
1. The minimum operating system is Solaris 2.3.
2. Install the first Fibre Channel Optical Module in Slot B.
Firmware Notes:
1. The FC/25S requires firmware equal to or greater than 1.33 to boot the SPARC
storage Array.
2. Firmware 1.33 is on FC25/S 501-2069-07 and 501-2553-03.
3. Use the OBP "sccsid" command to display the FCS25/S firmware level:
ok setenv fcode-debug? true
ok cd /io-unit@f,e1200000/sbi@0,0/SUNW,soc@3,0
ok sccsid type
1.18 94/03/15
ok device-end
4. Use the fc_update command to download the FC25/S firmware, then halt the
system and power cycle the SPARCstorage Array:
# /cdrom/ssa_2_1_sparc/fc_update/fc_update
5. The fc_update command is not supported on the SS4 or SS5.
Booting Notes:
1. Solaris 2.3 does not support booting from the Array Controller.
2. Solaris 2.4 Hardware: 3/95, SPARCstorage Array Software 2.1 and FC25/S
firmware greater than or equal to 1.33 are required to boot SPARCstorage
Array.
References:
1. Fibre Channel SBus Card Installation Manual, 801-6313-10.
2. Fibre Channel Optical Module Installation Manual, 801-6326-10.
3. Fibre Channel SBus Card Product Note, 802-3237-10.
4. SPARCstorage Array 2.0 CD Insert Product Note, 804-4793-11.
5. SPARCstorage Array 2.1 CD Insert Product Note, 804-4996-10.
6. SPARCstorage Array 2.1.1 Product Note, 802-2043-11.
7. SPARCstorage Array 2.1.1 CD Product Note, 802-5314-10.
SOLUTION SUMMARY:
INTERNAL SUMMARY: