Physical Specifications, Electrical Specifications, and Environmental
Requirements for the Ultra Enterprise 3000/4000/5000/6000 machines.
From Ultra Enterprise 6000/5000/4000 Systems Manual
Part NO.: 802-3845-10, May 1996
----------------------------------------------------------------------------
A.1 Physical Specifications
Table A-1. Cabinet Server Physical Specifications
------------------------------------------
U.S . Metric
------------------------------------------
Height 56 in 143 cm
Width 30 in 77 cm
Depth 39 in 99 cm
Weight 800 lb, approx 360 kg, approx
Power cord 15 ft. 4.6 m
------------------------------------------
Table A-2. Cabinet Server Clearance and Service Access
-----------------------
U.S. Metric
-----------------------
Front 48 in 122 cm
Rear 36 in 92 cm
Left 36 in 92 cm
Right 2 in 5 cm
-----------------------
Table A-3. Cabinet Server Shipping Specifications
--------------------------------------
U.S. Metric
--------------------------------------
Height 62.0 in 157 cm
Width 39 in 99 cm
Depth 44.5 in 113 cm
Weight 875 lb, approx 400 kg, approx
--------------------------------------
Table A-4 Standalone Server Physical Specifications
-----------------------------------------
U.S . Metric
-----------------------------------------
Height 13.5 in 34 cm
Width 19.7 in 50 cm
Depth 22 in 56 cm
Weight 150 lb, approx 68 kg, approx
Power cord 6 ft. 1.8 m
-----------------------------------------
Table A-5. Standalone Server Clearance and Service Access
---------------------
U.S. Metric
---------------------
Front 18 in 47 cm
Rear 18 in 47 cm
Left 6 in 16 cm
Right 6 in 16 cm
---------------------
Table A-6. Standalone Server Shipping Specifications
-------------------------------------
U.S. Metric
-------------------------------------
Height 19.0 in 48 cm
Width 23.8 in 60 cm
Depth 26.8 in 68 cm
Weight 160 lb, approx 72 kg, approx
-------------------------------------
A.2 Electrical Specifications
Table A-7. Cabinet Server Electrical Specifications
---------------------------------------------------------------------------
Parameter Value
---------------------------------------------------------------------------
Input current Voltage range 200-240 Vac
Current, maximum 24A
Current frequency range 47-63 Hz
Input power rating Total continuous power 3500W (with 3 drive trays)
Volt-Ampere rating 3700 VA
BTU rating 12,000 BTU
Power factor 0.92 - 0.96
Plug type U.S. NEMA L6-30P for 200-240 Vac
International 32A, single phase IEC 309,
connected for 220-240 Vac
---------------------------------------------------------------------------
Table A-8. Standalone Server Electrical Specifications
------------------------------------------------------------------------
Parameter Value
------------------------------------------------------------------------
Input current Voltage range 100-120 Vac or 200-240 Vac
Current, maximum 12A
Current frequency range 47-63 Hz
Input power rating Total continuous power 1370W
Volt-Ampere rating 1440 VA
BTU rating 4680 BTU
Power factor 0.92 - 0.96
Plug type U.S. NEMA 5-15P
International 10A, single phase IEC 320,
connected for 220-240 Vac
------------------------------------------------------------------------
A.3 Environmental Requirements
Table A-9. Cabinet Server Temperature, Humidity,
and Altitude Limits
----------------------------------------------------------------------
Operating Nonoperating
----------------------------------------------------------------------
Temperature 41F to 95F (5C to 40C) -4F to 140F (-20C to 60C)
Humidity 20% to 80% RH noncondensing, 93% RH
27C max wb
Altitude 9,843 ft. (3 km) 39,370 ft. (12 km)
----------------------------------------------------------------------
Table A-10. Standalone Server Temperature, Humidity,
and Altitude Limits
--------------------------------------------------------------------
Operating Nonoperating
--------------------------------------------------------------------
Temperature 41F to 104F (5C to 40C) -4F to 140F (-20C to 60C)
Humidity 20% to 80% RH noncondensing, 93% RH
27C max wb
Altitude 9,843 ft. (3 km) 39,370 ft. (12 km)
--------------------------------------------------------------------